Full text loading...
Pericardiocentesis
British Small Animal Veterinary Association , 229 (2024); https://doi.org/10.22233/9781913859145.2.55
/content/chapter/10.22233/9781913859145.ch2sec55
Pericardiocentesis
- From: BSAVA Guide to Procedures in Small Animal Practice
- Item: Procedures A to Z, pp 229 - 234
- DOI: 10.22233/9781913859145.2.55
- Copyright: © 2024 British Small Animal Veterinary Association
- Publication Date: March 2024
Abstract
This procedure is indicated in relief of pericardial tamponade and to obtain a sample of pericardial fluid for diagnostic evaluation.
/content/chapter/10.22233/9781913859145.ch2sec55
Figures
/content/figure/10.22233/9781913859145.ch2sec55.figP.1
Figure P.1:
A small stab incision should be made in the skin. © 2024 British Small Animal Veterinary Association
10.22233/9781913859145/figp230_1_thumb.gif
10.22233/9781913859145/figp230_1.png
Figure P.1:
A small stab incision should be made in the skin.
/content/figure/10.22233/9781913859145.ch2sec55.figP.2
Figure P.2:
The cannula and needle should be inserted through the stab incision. © 2024 British Small Animal Veterinary Association
10.22233/9781913859145/figp230_2_thumb.gif
10.22233/9781913859145/figp230_2.png
Figure P.2:
The cannula and needle should be inserted through the stab incision.
/content/figure/10.22233/9781913859145.ch2sec55.figP.3
Figure P.3:
A narrow-gauge sterile urinary catheter can be used to drain fluid from the pericardial sac © 2024 British Small Animal Veterinary Association
10.22233/9781913859145/figp231_1_thumb.gif
10.22233/9781913859145/figp231_1.png
Figure P.3:
A narrow-gauge sterile urinary catheter can be used to drain fluid from the pericardial sac
/content/figure/10.22233/9781913859145.ch2sec55.figP.4
Figure P.4:
The catheter introducer should be inserted through the skin incision. © 2024 British Small Animal Veterinary Association
10.22233/9781913859145/figp231_2_thumb.gif
10.22233/9781913859145/figp231_2.png
Figure P.4:
The catheter introducer should be inserted through the skin incision.
/content/figure/10.22233/9781913859145.ch2sec55.figP.5
Figure P.5:
The guidewire should be thread through the introducer catheter into the pericardium. © 2024 British Small Animal Veterinary Association
10.22233/9781913859145/figp231_3_thumb.gif
10.22233/9781913859145/figp231_3.png
Figure P.5:
The guidewire should be thread through the introducer catheter into the pericardium.
/content/figure/10.22233/9781913859145.ch2sec55.figP.6
Figure P.6:
The guidewire should be held as it is advanced into the pericardium. © 2024 British Small Animal Veterinary Association
10.22233/9781913859145/figp232_1_thumb.gif
10.22233/9781913859145/figp232_1.png
Figure P.6:
The guidewire should be held as it is advanced into the pericardium.
/content/figure/10.22233/9781913859145.ch2sec55.figP.7
Figure P.7:
The introducer catheter is removed leaving the guidewire in place. © 2024 British Small Animal Veterinary Association
10.22233/9781913859145/figp232_2_thumb.gif
10.22233/9781913859145/figp232_2.png
Figure P.7:
The introducer catheter is removed leaving the guidewire in place.
/content/figure/10.22233/9781913859145.ch2sec55.figP.8
Figure P.8:
(a) The catheter should be introduced and advanced into the pericardium over the guidewire. (b) The catheter in place. © 2024 British Small Animal Veterinary Association
10.22233/9781913859145/figp232_3_thumb.gif
10.22233/9781913859145/figp232_3.png
Figure P.8:
(a) The catheter should be introduced and advanced into the pericardium over the guidewire. (b) The catheter in place.
/content/figure/10.22233/9781913859145.ch2sec55.figP.9
Figure P.9:
The guidewire should be removed and the catheter left in place. © 2024 British Small Animal Veterinary Association
10.22233/9781913859145/figp232_4_thumb.gif
10.22233/9781913859145/figp232_4.png
Figure P.9:
The guidewire should be removed and the catheter left in place.
/content/figure/10.22233/9781913859145.ch2sec55.figP.10
Figure P.10:
The guidewire should be threaded through the needle into the pericardium. The guidewire must be held at all times. (Courtesy of Luca Ferasin) © 2024 British Small Animal Veterinary Association
10.22233/9781913859145/figp233_1_thumb.gif
10.22233/9781913859145/figp233_1.png
Figure P.10:
The guidewire should be threaded through the needle into the pericardium. The guidewire must be held at all times. (Courtesy of Luca Ferasin)
/content/figure/10.22233/9781913859145.ch2sec55.figP.11
Figure P.11:
The needle should be removed and the guidewire left in place. (Courtesy of Luca Ferasin) © 2024 British Small Animal Veterinary Association
10.22233/9781913859145/figp233_2_thumb.gif
10.22233/9781913859145/figp233_2.png
Figure P.11:
The needle should be removed and the guidewire left in place. (Courtesy of Luca Ferasin)
/content/figure/10.22233/9781913859145.ch2sec55.figP.12
Figure P.12:
The catheter should be threaded over the guidewire. (Courtesy of Luca Ferasin) © 2024 British Small Animal Veterinary Association
10.22233/9781913859145/figp233_3_thumb.gif
10.22233/9781913859145/figp233_3.png
Figure P.12:
The catheter should be threaded over the guidewire. (Courtesy of Luca Ferasin)
/content/figure/10.22233/9781913859145.ch2sec55.figP.13
Figure P.13:
The guidewire should be removed and the catheter left in place. (Courtesy of Luca Ferasin) © 2024 British Small Animal Veterinary Association
10.22233/9781913859145/figp233_4_thumb.gif
10.22233/9781913859145/figp233_4.png
Figure P.13:
The guidewire should be removed and the catheter left in place. (Courtesy of Luca Ferasin)
/content/figure/10.22233/9781913859145.ch2sec55.figP.14
Figure P.14:
A closed drainage system should be created by attaching a 3-way tap, extension tubing and syringe. © 2024 British Small Animal Veterinary Association
10.22233/9781913859145/figp234_1_thumb.gif
10.22233/9781913859145/figp234_1.png
Figure P.14:
A closed drainage system should be created by attaching a 3-way tap, extension tubing and syringe.
/content/figure/10.22233/9781913859145.ch2sec55.figP.15
Figure P.15:
The fluid collected should be placed into a measuring container. © 2024 British Small Animal Veterinary Association
10.22233/9781913859145/figp234_2_thumb.gif
10.22233/9781913859145/figp234_2.png
Figure P.15:
The fluid collected should be placed into a measuring container.